Custom Commercial Venting

Venting Options for Custom Commercial Fireplaces

Montigo Custom BF Series, C View and Prodigy fireplaces are engineered systems that include an appropriately sized Power Vent of your chosen style (see Page 3 of the Power Vent Guide).

Our engineers review your unique vent run and size the power vent based on the needs of the particular project. The Montigo supplied power vent is the only power vent that can be used.

Venting for a specific fireplace must be dedicated – you CANNOT combine the fireplace’s venting with other venting in the building even if the venting is for another fireplace. You also cannot tie the fireplace’s intakes into any other equipment’s intake/louver.

If you have a unique custom fireplace venting requirement please contact Montigo to discuss the available options.

Power Vent Types for Custom Fireplace Vent Runs

Please see the Power Vent Guide for further information about these power vent types and more detailed requirements for custom fireplace venting and placement.

Roof Mounted Power Vent

Roof Mounted Power Vent
(SBFPV-R)

Positioned on the roof and blows flue gas out horizontally around the power vent (see Figure A in the Power Vent Guide for placement requirements)


Roof Mounted Updraft Power Vent
(BFUDPV) *C View ONLY

Positioned on the roof and blows flue gas out vertically up from the vent (see Figure C in the Power Vent Guide for placement requirements)


Wall Mounted Power Vent
(SBFPV-W)

Positioned on the outside of the building wall, this vent protrudes from the wall and blows flue gas perpendicular to the wall (see Figure A in the Power Vent Guide for placement requirements)


Flush Wall Mounted Power Vent
(FMPVL-W) *C View ONLY

Mounted flush on the outside of the building wall, this is a discreet option provided you have the clearances required (see Figure B in the Power Vent Guide for placement requirements)


In-line Mounted Power Vent
(INPV [*C View Only] & INGPV)

Mounted in-line to your flue gas vent run and inside the building when an external power vent is not a viable option. Place as close to the termination as possible, and in an area where noise is not a concern (see Figure B in the Power Vent Guide for exhaust placement requirements)


Pro Help Desk

SUPPORT FOR ARCHITECTS, BUILDERS, CONTRACTORS, DESIGNERS, AND REMODELING PROFESSIONALS

Need help finding the right hearth solution for your residential or commercial plans? Fill out the form below to submit a professional design, technical, or pricing query to Montigo’s custom commercial engineering team.

PRO HELP DESK

If you are a homeowner/consumer looking for customer support please use our tech support form.

Where to Buy

For residential fireplace purchases, customer service, installation assistance, and tech support, please contact an Authorized Montigo Dealer in your area.

Please enter a valid postal / zip code.